Importance of structural design of multi-storey prefabricated workshop building

Time:[2022-4-29]  Hits:2327

In recent years, with the development of the diversity of the world economy, the industrial production of various countries and regions has also been continuously improved, and the complexity of the process layout is a revolutionary change for the industrial workshop buildings with single production function and simple building layout in the past; At the same time, the popularization of computers and the integration and simplification of structural calculation software have solved the complex and cumbersome structural calculation problems. As a result, multi-storey and even high-rise productive industrial buildings with large span, large space and complex building layout have emerged. Under the background of such rapid development, the rational selection of building structure layout and design parameters has played an important role in structural design.

1. Characteristics of multi-storey prefabricated workshop building

1.1 plane structure layout and column grid layout

In the plane layout of multi-storey prefabricated workshop building, usually in order to meet the process requirements: the structural layout is irregular, the pole network is irregular, and the beam layout is irregular, so there is the phenomenon of opening holes on the main stressed components according to the process requirements. At the same time, the internal space of the workshop building is generally large, and the column spacing is mostly 6 ~ 12m; The same part has the design of pulling column; The column spacing will increase to more than 18m. This makes the force transmission of the structure complex, the force is not clear, and the phenomenon of stress concentration is easy to occur in the design.

1.2 vertical structure layout and floor height

The storey height of multi-storey prefabricated workshop building is large, which can reach 4 ~ 8m, and there are often staggered floors and interlayer in the vertical layout, and large holes are opened in the floor, which makes the floor unable to provide sufficient in-plane stiffness, and the effective mass of the structure is unevenly distributed along the vertical direction. Under the action of earthquake, the structure may produce "short column effect", which makes the horizontal shear force of local column section become the control factor of section design.

1.3 various types of loads

The concentrated load of industrial workshop building mainly includes the self weight of equipment, and sometimes the vibration disturbance of equipment needs to be considered, and the dynamic calculation is carried out according to the requirements of the specification. Suspension load mainly includes pipeline load and crane load, and sometimes the pipeline also produces horizontal load and bending moment. The plate surface load is mainly based on the requirements of production technology. There are different values of live load on the ground of different production buildings, but this kind of live load is generally greater than that in civil buildings.


1.4 floor and foundation form

The cast-in-situ reinforced concrete floor is generally adopted for the floor of industrial workshop building. However, due to the equipment load requirements proposed by the process, the floor may have holes or local thickness changes. The foundation form of the powerhouse mostly adopts the independent foundation under the column and the strip foundation under the column. If the bearing capacity of the foundation is low, the lime soil compaction pile, sand pile and other methods can be used to deal with it, or the cast-in-place pile can be used to act directly on the hard soil layer.

1.5 light envelope

Generally, the enclosure structure of industrial workshop building is not used as a load-bearing system, and light materials are usually used. The roof structure mostly adopts steel truss purlin system with light insulation layer. This light enclosure material is beneficial to reduce the self weight of the structure and reduce the seismic response.

Copyright:佛山市勝邦鋼結(jié)構(gòu)有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號
主站蜘蛛池模板: 操操爱| 黄色片网站免费在线观看 | 亚洲免费在线视频观看 | 99精品国产兔费观看久久99 | 欧美日韩视频在线第一区 | 亚洲已满18点击进入在线观看 | 国产真实女人一级毛片 | 精品国产第一国产综合精品 | 国产va免费高清在线观看 | 有没有www动漫在线观看高清 | 福利 网红 精品 免费 高清 | 黄色成人在线网站 | 日韩精品欧美一区二区三区 | 69av视频| 欧美一级在线 | 4438亚洲全国最大成人网 | va亚洲va欧美va国产综合 | 亚洲 另类 在线 欧美 制服 | 成人综合激情网 | 国产精品欧美在线不卡 | 东台人才招聘网最新招聘2023 | 成人久久影院 | 国产欧美在线观看 | 97视频在线免费观看 | 欧美地区一二三区 | 三级视频网站在线观看视频 | 丁香婷婷在线 | 六月婷婷综合 | 久久网国产| 91国偷自产一区二区三区蜜臀 | 国产欧美日韩免费一区二区 | 国产欧美精品三区 | 青青草原社区 | 欧美视频免费一区二区三区 | 午夜宅宅网 | 亚洲欧洲日产国码在线观看 | 日本高清免费中文字幕不卡 | h版欧美一区二区三区四区 h版欧美大片免费观看 | 欧美在线观看一区二区三 | 恋爱综合症电视剧泰剧在线观看 | 亚洲一区二区三区日本久久九 |